FRBC.UsageForecastElement

The FRBC.UsageForecastElement type of the S2 energy flexibility standard: its fields, their types, and which are required.

This page is generated from the crate itself, so it cannot disagree with the code.

FieldTypeRequiredDescription
durationDurationyesIndicator for how long the given usage_rate is valid.
usage_rate_expectedfloatyesThe most likely value for the usage rate; the expected increase or decrease of the fill_level per second. A positive value indicates that the fill level will decrease due to usage.
usage_rate_lower_68PPRfloatnoThe lower limit of the range with a 68 % probability that the usage rate is within that range. A positive value indicates that the fill level will decrease due to usage.
usage_rate_lower_95PPRfloatnoThe lower limit of the range with a 95 % probability that the usage rate is within that range. A positive value indicates that the fill level will decrease due to usage.
usage_rate_lower_limitfloatnoThe lower limit of the range with a 100 % probability that the usage rate is within that range. A positive value indicates that the fill level will decrease due to usage.
usage_rate_upper_68PPRfloatnoThe upper limit of the range with a 68 % probability that the usage rate is within that range. A positive value indicates that the fill level will decrease due to usage.
usage_rate_upper_95PPRfloatnoThe upper limit of the range with a 95 % probability that the usage rate is within that range. A positive value indicates that the fill level will decrease due to usage.
usage_rate_upper_limitfloatnoThe upper limit of the range with a 100 % probability that the usage rate is within that range. A positive value indicates that the fill level will decrease due to usage.