The PEBC.EnergyConstraint type of the S2 energy flexibility standard: its fields, their types, and which are required.

This page is generated from the crate itself, so it cannot disagree with the code.

FieldTypeRequiredDescription
commodity_quantityCommodityQuantityyesType of power quantity which applies to upper_average_power and lower_average_power
idIDyesIdentifier of this PEBC.EnergyConstraints. Must be unique in the scope of the Resource Manager, for at least the duration of the session between Resource Manager and CEM.
lower_average_powerfloatyesLower average power within the time period given by valid_from and valid_until. If the duration is multiplied with this power value, then the associated lower energy content can be derived. This is the lowest amount of energy the resource will consume during that period of time. The Power Envelope created by the CEM must allow at least this much energy production (in case the number is negative). Must be greater than or equal to lower_average_power, and can be negative in case of energy production.
message_idIDyesID of this message
message_typestringyes
upper_average_powerfloatyesUpper average power within the time period given by valid_from and valid_until. If the duration is multiplied with this power value, then the associated upper energy content can be derived. This is the highest amount of energy the resource will consume during that period of time. The Power Envelope created by the CEM must allow at least this much energy consumption (in case the number is positive). Must be greater than or equal to lower_average_power, and can be negative in case of energy production.
valid_fromstringyesMoment this PEBC.EnergyConstraints information starts to be valid