PEBC.PowerConstraints

The PEBC.PowerConstraints type of the S2 energy flexibility standard: its fields, their types, and which are required.

This page is generated from the crate itself, so it cannot disagree with the code.

FieldTypeRequiredDescription
allowed_limit_rangesPEBC.AllowedLimitRange[]yesThe actual constraints. There shall be at least one PEBC.AllowedLimitRange for the UPPER_LIMIT and at least one AllowedLimitRange for the LOWER_LIMIT. It is allowed to have multiple PEBC.AllowedLimitRange objects with identical CommodityQuantities and LimitTypes.
consequence_typePEBC.PowerEnvelopeConsequenceTypeyesType of consequence of limiting power
idIDyesIdentifier of this PEBC.PowerConstraints. Must be unique in the scope of the Resource Manager, for at least the duration of the session between Resource Manager and CEM.
message_idIDyesID of this message
message_typestringyes
valid_fromstringyesMoment this PEBC.PowerConstraints start to be valid
valid_untilstringnoMoment until this PEBC.PowerConstraints is valid. If valid_until is not present, there is no determined end time of this PEBC.PowerConstraints.