PPBC.PowerSequence
The PPBC.PowerSequence type of the S2 energy flexibility standard: its fields, their types, and which are required.
This page is generated from the crate itself, so it cannot disagree with the code.
| Field | Type | Required | Description |
|---|---|---|---|
abnormal_condition_only | boolean | yes | Indicates if this PPBC.PowerSequence may only be used during an abnormal condition |
elements | PPBC.PowerSequenceElement[] | yes | List of PPBC.PowerSequenceElements. Shall contain at least one element. Elements must be placed in chronological order. |
id | ID | yes | ID of the PPBC.PowerSequence. Must be unique in the scope of the PPBC.PowerSequnceContainer in which it is used. |
is_interruptible | boolean | yes | Indicates whether the option of pausing a sequence is available. |
max_pause_before | Duration | no | The maximum duration for which a device can be paused between the end of the previous running sequence and the start of this one |